SFr. 72.00
€ 77.76
BTC 0.0013
LTC 1.071
ETH 0.0226


bestellen

Artikel-Nr. 32275587


Diesen Artikel in meine
Wunschliste
Diesen Artikel
weiterempfehlen
Diesen Preis
beobachten

Weitersagen:



Autor(en): 
  • Oltion Korini
  • Seismic Assessment of Masonry Buildings Using Nonlinear Analysis: Nonlinear 3D pushover analysis of unreinforced masonry buildings using SAP2000 softw 
     

    (Buch)
    Dieser Artikel gilt, aufgrund seiner Grösse, beim Versand als 2 Artikel!


    Übersicht

    Auf mobile öffnen
     
    Lieferstatus:   i.d.R. innert 7-14 Tagen versandfertig
    Veröffentlichung:  September 2016  
    Genre:  Naturwissensch., Medizin, Technik 
    ISBN:  9783659915024 
    EAN-Code: 
    9783659915024 
    Verlag:  LAP Lambert Academic Publishing 
    Einband:  Kartoniert  
    Sprache:  English  
    Dimensionen:  H 220 mm / B 150 mm / D 9 mm 
    Gewicht:  227 gr 
    Seiten:  140 
    Zus. Info:  Paperback 
    Bewertung: Titel bewerten / Meinung schreiben
    Inhalt:
    Masonry is one of the most commonly used materials not only in Albania but also worldwide for the construction of low to mid rise buildings. Recent strong earthquakes in different countries have shown that masonry buildings suffered severe damage and caused loss of lives. Therefore it is important to assess the seismic performance of these buildings and based upon this evaluation, techniques should be developed for the strengthening of building stock against future earthquake damages. The purpose of this study is to evaluate the seismic performance of three residential buildings with selected template designs in Albania considering the nonlinear behavior of masonry. A nonlinear modeling method is developed in SAP2000 software and calibrated by 3Muri software. The capacity curves of the investigated buildings were determined by pushover analyses conducted in two principal directions. Seismic performance evaluation was carried out in accordance with the FEMA440 guidelines. The graphical-analytical procedure described there is used for performance evaluation. The analysis shows that two out of three selected buildings do not satisfy the required performance levels.

      



    Wird aktuell angeschaut...
     

    Zurück zur letzten Ansicht


    AGB | Datenschutzerklärung | Mein Konto | Impressum | Partnerprogramm
    Newsletter | 1Advd.ch RSS News-Feed Newsfeed | 1Advd.ch Facebook-Page Facebook | 1Advd.ch Twitter-Page Twitter
    Forbidden Planet AG © 1999-2024
    Alle Angaben ohne Gewähr
     
    SUCHEN

     
     Kategorien
    Im Sortiment stöbern
    Genres
    Hörbücher
    Aktionen
     Infos
    Mein Konto
    Warenkorb
    Meine Wunschliste
     Kundenservice
    Recherchedienst
    Fragen / AGB / Kontakt
    Partnerprogramm
    Impressum
    © by Forbidden Planet AG 1999-2024