SFr. 52.50
€ 56.70
BTC 0.001
LTC 0.765
ETH 0.0199


bestellen

Artikel-Nr. 32946695


Diesen Artikel in meine
Wunschliste
Diesen Artikel
weiterempfehlen
Diesen Preis
beobachten

Weitersagen:



Autor(en): 
  • Jayakar Shetty
  • Vinay PavanKumar Kadavakolanu
  • Cheeranjeevi Reddy
  • Effect of retorque on initial torque loss and preload maintenance: Determination of initial torque loss and effect of retightenting on preload mainten 
     

    (Buch)
    Dieser Artikel gilt, aufgrund seiner Grösse, beim Versand als 2 Artikel!


    Übersicht

    Auf mobile öffnen
     
    Lieferstatus:   i.d.R. innert 7-14 Tagen versandfertig
    Veröffentlichung:  März 2016  
    Genre:  Naturwissensch., Medizin, Technik 
    ISBN:  9783659825064 
    EAN-Code: 
    9783659825064 
    Verlag:  LAP Lambert Academic Publishing 
    Einband:  Kartoniert  
    Sprache:  English  
    Dimensionen:  H 220 mm / B 150 mm / D 5 mm 
    Gewicht:  137 gr 
    Seiten:  80 
    Zus. Info:  Paperback 
    Bewertung: Titel bewerten / Meinung schreiben
    Inhalt:
    There is sufficient documentary evidence to prove that the dental implant treatment has predictable prognosis. In spite of the high rate of success, failures do occur with dental implants. The most commonly reported mechanical failure is related to abutment screw loosening. There are several factors attributed to screw loosening. One factor is the optimum preload applied which keeps the screw threads tightly adapted to the screw mating counterpart. Screw loosening appears to be a minor incident but the resultant complications should not be underestimated. Clinically, screw loosening is unpleasant for the patient, time consuming and expensive for the operating professional. The retrieval of these failing prosthesis is not easily achieved and occasionally it ends up with the sacrifice of the crown. Retightening of abutment screws after initial torque prevents initial torque loss due to friction between the screw mates and subsequent screw loosening by micro motion. This phenomenon is not fully explored. Hence the present study is designed to evaluate the initial torque loss and effect of retightening and mechanical cyclic loading on preload maintenance in titanium implant system.

      



    Wird aktuell angeschaut...
     

    Zurück zur letzten Ansicht


    AGB | Datenschutzerklärung | Mein Konto | Impressum | Partnerprogramm
    Newsletter | 1Advd.ch RSS News-Feed Newsfeed | 1Advd.ch Facebook-Page Facebook | 1Advd.ch Twitter-Page Twitter
    Forbidden Planet AG © 1999-2024
    Alle Angaben ohne Gewähr
     
    SUCHEN

     
     Kategorien
    Im Sortiment stöbern
    Genres
    Hörbücher
    Aktionen
     Infos
    Mein Konto
    Warenkorb
    Meine Wunschliste
     Kundenservice
    Recherchedienst
    Fragen / AGB / Kontakt
    Partnerprogramm
    Impressum
    © by Forbidden Planet AG 1999-2024